Adjustment of heat metering units. Thermal energy measuring unit

One of the most effective methods, which allows to reduce the wasteful use of heat, is considered a way to account for the consumption of thermal energy. To do this, a special set of measuring aids is used, which is installed on the heating networks - the heat energy accounting unit.

It should be noted that the installation of UUTE itself is not an energy-saving technology. This is more a commercial step, however, by allowing users of the heat network to control the parameters and consumption of heat energy, this method stimulates the reduction of heat consumption, allows saving money and planning savings.

Thermal energy suppliers also use thermal units   accounting for consumption control. This allows them to promptly detect heat leakage and take appropriate measures. At the same time, the relatively high price of UUTE pays off very quickly in the form of saved money.

Structurally, the heat energy metering unit is a set of "modules" installed (embedded) in the pipeline. According to the method of connecting hot water supply to consumers, the thermal accounting nodes are divided into:

  1. UUTE for closed systems, in which water is used only as a coolant;
  2. UUTE for open systems, where water abstraction of water can be partially or completely carried out for other needs.

The heat metering unit consists of a heat calculator, instrumentation instruments, stop valves, flow, heat and pressure converters. Sometimes the design of the UUTE takes into account the use of GSM-, GPRS-, Ethernet-controllers, which make it possible to monitor the indicators and the state of the heat network remotely.

The modern market offers a variety of heat metering systems from different manufacturers: Magica, KM-5, SA-94, VTK, etc. One of the easiest to install and operate, functional, reliable and durable is the thermal energy measuring center of the plant "Teplovizor" .

The thermal energy measuring unit VIST, depending on the modification, can be used not only in water heating networks, but also in cold and hot water supply systems, in systems with a change in flow direction and with the function of switching the limits for measuring the heat consumption according to the preset regime.

Thermal energy meter in ITP, TSC

With the increase in prices for thermal energy   The devices of heat metering have become more and more in demand. Places where it is most convenient to install UUTE - thermal points, so the heat metering unit at the central heating station or ITP today is not uncommon.

The UUTE used in ITP, as a rule, includes the following main elements:

  • heat calculator;
  • electromagnetic flowmeter;
  • thermocouple;
  • overpressure transducer.
  • devices for indicating and monitoring temperature and pressure;
  • power supplies for flowmeters and other devices;
  • stop valves.

The heat metering unit at the ITP or TSC is part of a complex and ramified heat supply system. Their design, installation and operation, including the maintenance of the UTE, must be carried out by highly qualified personnel in full accordance with normative documents. Before start-up, all heat points with UTE should be approved by Rostechnadzor.

In the absence of any shortcomings, inconsistencies, inaccuracies and comments, Rostekhnadzor, after processing the necessary documents, issues a permit to put the facility into operation. However, if, for some reason, the heating installation has not been connected for 3 months, the permit for access is canceled.

In our company, the installation of the heat energy metering unit is performed only for the project. Our specialists have the necessary qualifications and extensive experience in installing heat metering units of various manufacturers.

The installation of the heat metering unit is usually performed within the scope of installation of the heat point equipment.

The heat energy accounting unit (UUTE) is necessary for making accurate calculations with the heat supply organization for the consumed heat energy. When installing the UUTE, payment is based on actual consumption, rather than calculated values.

Installation of the UUTE from the company "Energomontazh" is:

  • Installation of the heat energy meter in full accordance with design decision   and terms of reference
  • Initial adjustment
  • Full package of documentation
  • Convenience of future equipment maintenance
  • Delivery and setting for commercial registration in the heat supply organization and obtaining the Act of Tolerance
  • Training of personnel in working with equipment

Customer feedback

OJSC "ELTESA"

"When choosing a company, we, first of all, based on the optimal ratio of the price and quality of the work performed.

During our cooperation, we were convinced that the technical equipment and quality of work are at a high level, all work is carried out in compliance with the rules and safety regulations. "

Director of LLC "TUKS MOSPROMSTROY" DA Shavkov

Examples of installing heat metering units

The order of installation of UUTE

  Development and approval of the project you can order from us or provide us with your agreed project. Purchase and delivery of equipment We purchase equipment according to the project specification and deliver them to your facility. We reduce the time at this stage to a minimum due to the availability of components in our own warehouse and our own logistics. Welding and assembly work We make a cut-off of the stop valves and devices in the pipelines. We mount the grounding system, if necessary. Electric installation work   We install electric boards, lay cable lines and connect devices to a thermal calculator. At this stage, the installation of the UUTE can be considered complete. Programming and setup We set up a heat meter to work on your facility. We adjust the operation of the sensors. Setting for commercial accounting and obtaining the act of access to operation We provide ready-made UUTE inspectors and obtain an access certificate. Training of personnel When the installation of the heat metering unit is completed and the equipment is approved for operation, we show the basic methods of working with equipment. Service We offer our services for and UUTE.

Equipment for installation of a heat metering unit

The choice of the scheme of work of the accounting unit and equipment takes place at the design stage. We have experience in installing UUTE for more than 10 years and know the features of installing equipment from different manufacturers.

Free of charge we advise on accessories

The main element of the heat metering unit is a heat meter or heat calculator. The most common type of heat meter is electromagnetic.

It simultaneously registers the volume, mass, amount of energy consumed, the temperature of the forward and return pipeline. Data can be displayed on an external display with hourly, daily or monthly intervals.

We have experience in installing heat metering units with thermal calculators of various manufacturers - VIST, SA-93/94, KM-5, MKTS, MAGICA.

ASWEGA - «SA-94/3 Intellect« MKTS »CJSC« NPO Teplovizor »-« VIS.T »« LLC «NPF» ECOS »-« Magika »

In addition to the thermal calculator of UUTE, it can also include:

  • tachometric converters - measurement of coolant flow,
  • pressure sensors - measurement of pressure in pipelines,
  • thermal converter or a set of thermal converters for - measurement of temperature and temperature differences in pipelines,
  • GSM / GPRS-modem - transfer of readings from the heat scintillation to your PC,
  • printer - printing of the statements directly from the heat meter,
  • stop valves.

Cost of installation of UUTE

The preliminary price of the heat metering unit you can see in the page.

The initial data for the evaluation of the cost of UUTE are:

  1. project,
  2. results of visual inspection of the object.

Accounting for thermal energy in the energy sector is at the heart of energy-saving measures. The account of thermal energy is necessary for maintenance of calculations for consumed thermal energy between the subscriber and a heat supply organization. It happens that the calculated consumption exceeds the actual consumption. This is due to the fact that suppliers of thermal energy in the calculation of thermal loads overestimate their values, writing off additional costs for consumers. Installation of heat metering devices avoids such situations.

Measures for recording and recording heat consumption are organized with a view to:

  • Implementation of financial settlements between suppliers and consumers of thermal energy.
  • Control over the thermal and hydraulic operating modes of the systems, heat supply and heat consumption.
  • Control over the rational use of thermal energy.
  • Documenting the parameters of the heat schemes: flow, temperature and pressure of the coolant.

Designations of the scheme of the heat energy metering unit:
  1. Heat meter
  2. Primary flow transmitter
  3. Thermocouple in the supply and return pipelines
  4. Thermometer
  5. Manometer
  6. Mesh-magnetic filter
  7. Gate valve

Thus, the heat metering unit allows:

1. Get real-time data on the amount of heat consumed.
  2. Implement various schemes of energy management in the enterprise.
  3. Fix any deviation of the values.
  4. To predict the value of energy accounting values ​​in heat schemes for the purpose of planning
  power consumption.

Additions on the topic:
  Permitting the operation of the heat energy meter at the consumer
  The operation of the heat energy meter at the consumer
  An example of a daily account of heat consumption parameters.

Maintenance of the heat metering unit includes the following main works:

1. Connecting the readers, taking readings
  2. Preliminary analysis of the results.
3. Analysis of errors and determining the causes of their occurrence.
  4. Verification of compliance with technological parameters, comparison of indicators T1 and T2 coolant thermometers.
  5. Checking the integrity of the seals.
  6. Remove dust and dirt.
  7. Check the ground contacts, clean the filters, top up the oil in the sleeves.
  8. Issuance of recommendations for the operation of internal networks.

According to the agreement with the Customer, the list of works on maintenance of the heat metering unit can be expanded accordingly.

Installation of heat metering units allows you to interact on payment issues with heat supply organizations strictly according to data removed from heat meters. If your enterprise or facility does not have commercial accounting, then you have to pay for it at the rates reflected in the heat supply contract. It should be noted that when switching to commercial accounting, each owner of a heat facility will feel tangible savings in monetary resources, as heat accounting centers can, on average, reduce costs by one third.

Installing heat-capturing devices will not only provide monthly savings due to the difference between the tariff and the actual heat energy consumed, but will also help save money by monitoring and terminating heat losses in your networks.

Now it is a well-known fact that the main measure of energy saving is its reliable accounting. It is he who helps to limit the cost of paying for the consumed heat energy, although it does not directly reduce the level of its consumption. Practice shows that the installation of accounting nodes entails a visible material benefit. This is due to the fact that heat suppliers tend to overestimate their indicators, trying to shift their costs to the consumers' shoulders. The installation of heat metering units will help to fix these discrepancies and pay only for the heat energy that was actually used by you.

The issue of installing heat meters has long been one of the most urgent for consumers of thermal energy. Is it really important and expedient to install the UUTE? We are confident that the installation of metering devices will allow consumers to easily monitor their costs, always visually see how much heat, and hot water   was actually consumed for any period of time. Accordingly, you will be paid only what was actually spent, and not lost on the way from the supplier to the end user.

Competent and certified employees of the company "KIPOVETS" will perform plumbing and other works in the field of installation and adjustment of accounting equipment, will install the UUTE, carry out their adjustment and start-up, correctly put into operation. Our company will install a heat meter at your facility and perform the entire turnkey work package. We can develop a project from scratch and coordinate it with the company responsible for the heat supply. Among our services, a special place is occupied by the installation of heat metering units, their commissioning, launching or dismantling. We will hand over the finished object to the heat supply organization and receive for you the Acceptance Certificate for the energy metering device, we are engaged in servicing the UTE, we accept orders for the verification of heat-measuring devices.

Installation of the heat metering units in the company KIPOVETS is entrusted to the real experienced masters. For all types of work, our company gives a 100% guarantee. All the equipment that we use in our work is modern, high-quality and high-precision. Installation of heat meters is carried out by us at a variety of sites. We install devices that are certified and have an acceptable cost, so our services are invariably in high demand. We managed to minimize the time of installation of our equipment by using new technologies in our work.

Installation of heat meters

The installation of the heat energy metering unit (UUTE) allows to save money. Every year, the requirements of heat supply organizations for the installation of UUTE are complicated. In this environment, you need to trust work in this area only for professionals in their field. It is necessary to note the savings that the installation of UUTE gives.

Also, one should not forget about the technical obsolescence of already installed subscribers of thermal energy meters. Such equipment is often out of order, and this can not be foreseen. In this case, our organization is replacing the UUTE, in accordance with the technical task of the heat supply organization. Our organization establishes only certified heat metering devices in accordance with the current heat energy accounting rules and technical specifications. With the professional installation of the heat metering unit of our organization, you can competently save thermal energy.

Prices for UUTE

It may seem that the installation of the UUTE is costly and costly, but in the case of setting the load values ​​of the heat supply organization, which sometimes exceeds the actual heat consumption several times, the price of the node for thermal energy accounting is immediately negligible. In case of contacting our company, you can count on a low price for a heat metering unit. The cost of installing heat meters will not be high, which provides you with the opportunity not to damage your budget.

The prices for installation of heat meters in Moscow at the moment are almost the same for different organizations, but you need to trust professionals who are clearly versed in the rules of installing the UUTE so that they do not overpay. Our organization has been installing UTE since 1997 and has considerable experience in this business. Also our experience allows us to set a low price for the installation of heat meters. Also, one should not forget about the high cost of UTE equipment and trust the installation only for professionals in their field. The cost of installing a heat metering unit will always be lower than the costs associated with damage from the hands of lay people.

The cost of installation of heat metering devices (including the purchase of all necessary materials, installation, commissioning works, delivery to a heat supply organization):

Number of heat systems

Cost, rub.

One system

From 270000

Two systems

From 350,000

Three systems

From 390000

Check the quality of the meters

Buying a technique for themselves, many people always check its efficiency immediately and clearly track how reliable it is. And whatever the prices for heat metering units, they should also be checked for quality and trusted only by certified and certified manufacturers. Our organization provides acceptable prices, which will guarantee the quality of each heat meter provided.

  Loading...